Run the RV park numbers
How this works
Enter the gross acres and the state, and pick the county or city where our research holds a local rule. Then enter the site mix: full-hookup RV sites, partial-hookup sites with water and power but no sewer, RV sites with no hookups, and tent or primitive sites. The calculator returns a preliminary estimate for each part of the program a preliminary site plan carries in its site data table, and it names the rule behind every figure. The inputs stay in the link, so a result can be shared and reopened.
The calculator does not compute internal road length, a layout or pad sizes: no source in our research supplies a method for them. A drawn RV park site plan does that work on the actual parcel.
Sites per acre
The calculator estimates no site count from a density observed in approvals. The density statistics and clusters our research found are computed over a set of approvals that includes machine-written meeting summaries, which the research itself says should be replaced with staff reports before public use, so none of them is shown. The calculator checks the site mix you enter against any verified density cap instead, and lists the approvals below as evidence, not as a rate.
Four approvals with primary documents show the spread. The Uintah County Planning Commission approved Rhoades RV Park unanimously, with 38 RV sites on 1.71 gross acres, or 22.2 sites per gross acre [1]. The Grants Pass Urban Area Planning Commission approved Jantzer RV Park 7-0, with 87 RV sites on 5.83 gross acres, or 14.9 per acre [2]. In Palm Beach County, the West Atlantic RV Resort staff report counts 113 RV sites and 8 camping cabins, 121 in all, on 10.11 gross acres, or 12.0 per acre [3]. The Adirondack Park Agency approved Woods Hollow RV Park unanimously, with 277 sites on 83.4 acres, or 3.3 per acre [4]. The guide to RV sites per acre covers the planning side of these numbers.
Density caps and minimum park size
Where our research verified a density cap stated per acre, the calculator caps the count, names the cap and keeps the lowest where several apply. Florida caps RV parks at 25 RV units per gross acre statewide for new or modified parks, and sets 1,200 sf per RV space and 500 sf per tent space [5]. Local codes can be stricter. Palm Bay, Florida, caps RV parks at 15 RV sites per gross acre, with a 10 acre minimum park size [6]. Sutherlin, Oregon, allows 22 sites per acre, or 25 with a density bonus, with a 2 acre minimum [7]. Alamosa County, Colorado, allows 8 sites per acre on average, with a 12 acre minimum [8]. Parker County, Texas, requires a 5.0 acre minimum tract and allows 60 spaces maximum on a 5.0 acre tract [9], and the calculator shows that cap as written rather than turning it into a rate per acre. The Florida RV park page and the Polk County model project show the Florida cap on a drawn site.
Michigan requires a 1,200 sf minimum site area, 15 ft of road frontage per site and a 4 ft clear path around each unit in all campgrounds [10]. The calculator multiplies each minimum site area by the sites entered and reports the share of the gross area the sites alone take, before roads and amenities.
Electrical load under NEC Article 551
NEC 551.71 requires 30 A, 125 V receptacles at 70 percent of electrified sites and 50 A receptacles at 40 percent of new sites (20 percent of existing), with every 50 A site also carrying a 30 A receptacle [11]. The 50 A share for new sites was raised from 20 to 40 percent in the 2017 NEC [12]. Dedicated tent sites with 15 or 20 A supply may be excluded when computing the 30 A and 50 A percentages [13]. The calculator uses the minimum 50 A share unless you enter a count, and gives every other powered RV site a 20 A and a 30 A receptacle.
For the calculated load, 551.73(A) counts 12,000 VA per 50 A site, 3,600 VA per site with both 20 A and 30 A, 2,400 VA per site with 20 A only and 600 VA per dedicated tent site with 20 A only [14]. Table 551.73(A) demand factors fall from 100 percent at 1 site to 41 percent at 36 or more sites, and they do not apply to bathhouses, recreation buildings, pools and similar loads [14]. In a published worked example, 20 sites at 45 percent of 3,600 VA gives 1,620 VA per site, or 32,400 VA in total [15]; the first worked example below repeats it.
These NEC values come from secondary reproductions of the code tables, and the calculator labels them that way. Which NEC edition a state has adopted is not verified in our research, so each result states the edition logic it uses: the values from 2017 onward, with the earlier 20 percent share and 9,600 VA basis for a 50 A site shown beside them [12, 14].
Water and wastewater design flows
The calculator multiplies the sites of each kind by the state's design flow, adds them, and compares the total with the state's review thresholds. Texas sets 50 gpd per travel trailer or RV park space, or 40 gpd with water-saving devices, and per-person rates for parks with a bathhouse (15 gpd, or 12 with devices) and without one (10 gpd, or 8) [16]. Its Chapter 285 on-site sewage rules apply to an RV park only with combined wastewater flow of less than 5,000 gallons per day [16]. Michigan sets 75 gal per site for sites with water and sewer outlets and for sites served by service buildings, 30 gpd per primitive site and 150 gal per park model site [10]. Michigan wells must deliver at least 30 gpm, or the sum of 1 gpm per park model connection plus 0.5 gpm per other site connection if that is higher [10].
North Carolina's 18E table sets 100 gal per RV space, 70 gal per campsite served by a bathhouse and 150 gal per park model space [17]. Its 02T table for non-discharge permits sets 100 gal per campsite with hookups, 75 without, and 50 gal per space for a campground dump station [18]. The local health department may approve RV park systems up to 1,500 gpd, and state review is required above 3,000 gpd unreduced design daily flow, for unapproved advanced pretreatment or for any system receiving dump-station waste [19]. The North Carolina RV park and Texas RV park pages cover the rest of each state's approval path.
Every state applies at least the federal public water system test: at least 15 service connections, or regularly serving an average of at least 25 individuals daily at least 60 days a year [20]. The calculator compares persons only when you enter persons per site, and it compares the sites with a water hookup against the connection test while stating that whether each hookup is one service connection is not verified in our research. Partial-hookup sites have no category in any verified table, so a total that leaves them out says so.
Fixtures, traffic, roads and parking
Florida requires, per park, 1 toilet and 1 urinal for men and 2 toilets for women, with the same set repeated for each 25 non-self-contained spaces or fraction, and 1 dump station per 100 spaces or fraction, or 1 per 250 spaces or fraction when more than 50 percent of spaces have sewer hookups [5]. A full-hookup, self-contained-only park may file an exemption letter (64E-15.005(6)) [5]. The calculator counts the sites without a sewer hookup as the non-self-contained spaces, and says so. Michigan requires a sanitary station, and for a primitive campground 1 privy per sex plus a water outlet per 25 sites [10].
For traffic, the calculator multiplies the occupied sites by the ITE PM peak hour rate for land use 416, Campground/Recreational Vehicle Park: 0.27 trips per occupied campsite in the 11th Edition (2021), as a city fee table republishes it [21]. It is a published trip rate from a thin dataset of 6 studies, not a code requirement [22].
Road widths start from NFPA 1194, a model standard for recreational vehicle parks and campgrounds [23]. For roads designed for all camping unit types and sizes, it sets 10 ft per traffic lane and 8 ft per parallel parking lane, and roads leading to accessory structures need 20 ft of unobstructed width and 13.5 ft of vertical clearance [23]. Adopted codes set their own widths. Oregon sets 10 ft per traffic lane and 10 ft per parking lane on park streets used by the public [24]. Fruita, Colorado, which adopts NFPA 1194 by reference, requires 28 ft two-way roads and 20 ft one-way roads [25]. TxDOT's Table 4-1 gives the MH/B, a motor home with a boat trailer, a 49.8 ft design radius and a 35 ft inside radius [26]; which design vehicle should govern an RV park's loop roads is not stated there and is not verified in our research.
Michigan's campground rules require 1.5 parking spaces per site, on sites or in a separate lot [10]. Tucson requires 1 parking space per campsite [27], Houston's Sec. 26-492 does not codify the use [28], and Milwaukee's Table 295-403-2-a has no row for it [29]; the parking requirements lookup covers other city rules. The campground site plan and glamping site plan pages cover the tent and cabin side of a program.
The rules in the calculator
120 verified code values and 45 reference values, as researched on October 11, 2026. Each value is stored exactly as its source writes it, with its citation; reference values carry their label: a model standard, a secondary reproduction of a code table, agency guidance, a published trip rate or a figure observed in approvals.
Density caps and minimum park size
| Jurisdiction | Rule | Value as stored | Unit | Condition | Citation |
|---|---|---|---|---|---|
| Alamosa County, Colorado | Density cap | 8 | sites per acre | on average | LUDC text amendment[8] |
| Alamosa County, Colorado | Minimum park size | 12 | acres | minimum park size | LUDC text amendment[8] |
| Florida | Density cap | 25 | RV units per gross acre | maximum, statewide; new or modified parks | 64E-15.002(3)(b)[5] |
| Duval County, Florida | Density cap | 25 | self-contained spaces per acre | maximum, temporary RV parks | Sec. 460.304 to 460.305[33] |
| Palm Bay, Florida | Density cap | 15 | RV sites per gross acre | maximum | Palm Bay Code §174.045[6] |
| Palm Bay, Florida | Minimum park size | 10 | acres | minimum park size | Palm Bay Code §174.045[6] |
| Sutherlin, Oregon | Density cap | 22 | sites per acre | maximum without density bonus | Sutherlin Municipal Code 12.40.090[7] |
| Sutherlin, Oregon | Density cap | 25 | sites per acre | maximum with density bonus | Sutherlin Municipal Code 12.40.090[7] |
| Sutherlin, Oregon | Minimum park size | 2 | acres | minimum park size | Sutherlin Municipal Code 12.40.090[7] |
| Parker County, Texas | Minimum park size | 5.0 | acre minimum tract | minimum tract for an RV park | Parker County Infrastructure Requirements for Recreational Vehicle Parks[9] |
| Parker County, Texas | Density cap | 60 | spaces maximum on a 5.0 acre tract | maximum on a 5.0 acre tract | Parker County Infrastructure Requirements for Recreational Vehicle Parks[9] |
A statewide density cap is verified in our research for Florida only. The calculator computes a cap stated per acre; a cap stated for a tract, or for temporary parks, is shown as the code states it.
Site geometry and road widths
| Jurisdiction | Parameter | Value as stored | Unit | Condition | Citation |
|---|---|---|---|---|---|
| National | Traffic lane width | 10 (model standard) | ft per traffic lane | roads designed for all camping unit types and sizes | NFPA 1194 §5.1.2, NFPA 1194, 2021 ed.[23] |
| National | Parking lane width | 8 (model standard) | ft per parallel parking lane | roads designed for all camping unit types and sizes | NFPA 1194 §5.1.2, NFPA 1194, 2021 ed.[23] |
| National | Road to accessory structures, width | 20 (model standard) | ft | unobstructed width, roads leading to accessory structures | NFPA 1194 §5.1.2.2, NFPA 1194, 2021 ed.[23] |
| National | Road to accessory structures, vertical clearance | 13.5 (model standard) | ft | vertical clearance, roads leading to accessory structures | NFPA 1194 §5.1.2.2, NFPA 1194, 2021 ed.[23] |
| National | One-way road width | 10 (model standard) | ft | one-way road, no parking lanes (derived from 10 ft per lane) | NFPA 1194 §5.1.2, NFPA 1194, 2021 ed.[23] |
| National | Two-way road width | 20 (model standard) | ft | two-way road, no parking lanes (derived from 10 ft per lane) | NFPA 1194 §5.1.2, NFPA 1194, 2021 ed.[23] |
| Fruita, Colorado | Minimum site area | 1,500 | sf | per space | Fruita Municipal Code Ch. 17.33 (17.33.030, 17.33.080)[25] |
| Fruita, Colorado | Minimum site width | 25 | ft | wide per space | Fruita Municipal Code Ch. 17.33 (17.33.030, 17.33.080)[25] |
| Fruita, Colorado | Car pad | 20 x 9 | ft | car pad per space | Fruita Municipal Code Ch. 17.33 (17.33.030, 17.33.080)[25] |
| Fruita, Colorado | RV pad | 35 x 12 | ft | RV pad per space | Fruita Municipal Code Ch. 17.33 (17.33.030, 17.33.080)[25] |
| Fruita, Colorado | Separation between units | 10 | ft | between units | Fruita Municipal Code Ch. 17.33 (17.33.030, 17.33.080)[25] |
| Fruita, Colorado | Two-way road width | 28 | ft | two-way roads | Fruita Municipal Code Ch. 17.33 (17.33.030, 17.33.080)[25] |
| Fruita, Colorado | One-way road width | 20 | ft | one-way roads | Fruita Municipal Code Ch. 17.33 (17.33.030, 17.33.080)[25] |
| Florida | Minimum site area | 1,200 | sf | per RV space; new or modified parks | 64E-15.002(3)(a) to (c)[5] |
| Florida | Minimum tent site area | 500 | sf | per tent space; new or modified parks | 64E-15.002(3)(a) to (c)[5] |
| Michigan | Minimum site area | 1,200 | sf | minimum site area, all campgrounds | R 325.1556(1)[10] |
| Michigan | Minimum road frontage per site | 15 | ft | minimum road frontage per site | R 325.1556(1)[10] |
| Michigan | Access to a road | must abut a roadway unless a walk-in site | R 325.1556(1)[10] | ||
| Michigan | Clear path around each unit | 4 | ft | unobstructed path completely around each unit, measured outside sheds and awnings (slide-outs and awnings) | R 325.1556(4)[10] |
| Michigan | Road right-of-way | 20 | ft | minimum road right-of-way, all campgrounds | R 325.1558(1)[10] |
| Michigan | Parking per site | 1.5 | spaces per site | on sites or in a separate lot | R 325.1558(2)[10] |
| Oregon | Traffic lane width | 10 | ft per traffic lane | minimum; park streets used by the public | OAR 918-650-0045(4)[24] |
| Oregon | Parking lane width | 10 | ft per parking lane | park streets used by the public | OAR 918-650-0045(4)[24] |
| Oregon | Separation between units | 10 | ft | from other camping vehicles or tents, buildings, and awnings or carports on adjacent spaces | OAR 333-031[34] |
| Oregon | Setback from a street boundary | 10 | ft | from boundary on a public street | OAR 333-031[34] |
| Oregon | Setback from other property lines | 5 | ft | from other property lines | OAR 333-031[34] |
| Parker County, Texas | Separation between units | 12 | ft | at least, between RVs with slide-outs extended | Parker County Infrastructure Requirements for Recreational Vehicle Parks[9] |
Design flows
| State | Service and site type | Value as stored | Unit | Condition | Citation |
|---|---|---|---|---|---|
| Florida | Wastewater: full-hookup | 75 | gpd | per vehicle space, transient RV park, overnight stay with water and sewer hookup | Rule 62-6.008(1) Table I[35] |
| Florida | Wastewater: no-hookup | 50 | gpd | per vehicle space, transient RV park, without water and sewer hookup | Rule 62-6.008(1) Table I[35] |
| Florida | Wastewater: tent | tent spaces fall under the RV space definition in 64E-15.001(9) | not set separately: use the RV space flow | 64E-15.001(9)[5] | |
| Florida | Wastewater: park-model | a park model counts as an RV space under 64E-15.001(9) | not set separately: use the RV space flow | 64E-15.001(9)[5] | |
| Michigan | Wastewater: full-hookup | 75 | gal | per site, water and sewer outlets at each site (table 1A states flows in gallons per day) | Mich. Admin. Code R 325.1561(2)(a) to (d)[10] |
| Michigan | Wastewater: no-hookup | 75 | gal | per site, sites served by service buildings (table 1A states flows in gallons per day) | Mich. Admin. Code R 325.1561(2)(a) to (d)[10] |
| Michigan | Wastewater: primitive | 30 | gpd | per primitive site operated with a modern campground | Mich. Admin. Code R 325.1561(2)(a) to (d)[10] |
| Michigan | Wastewater: park-model | 150 | gal | per park model site, also single-sectional mobile homes (table 1A states flows in gallons per day) | Mich. Admin. Code R 325.1561(2)(a) to (d)[10] |
| Michigan | Wastewater: cabin | Camping cabins (under 400 sf, no water connection) carry no separate flow (agency guidance) | resort cabins with fixtures need EGLE evaluation | EGLE cabin guidance Rev. 8/2025[31] | |
| Michigan | Water: park | 30 | gpm | minimum well delivery for the campground, unless the per-connection sum is higher | R 325.1559(1) to (2)[10] |
| Michigan | Water: park-model | 1 | gpm | per park model or mobile home connection, summed with the other site connections; applies when the sum is higher than the 30 gpm minimum | R 325.1559(1) to (2)[10] |
| Michigan | Water: other-site | 0.5 | gpm | per other site connection, summed with the park model connections; applies when the sum is higher than the 30 gpm minimum | R 325.1559(1) to (2)[10] |
| North Carolina | Wastewater: full-hookup (onsite-18E) | 100 | gal | per space, travel trailer or RV in an RV park (table 1A states flows in gallons per day) | 15A NCAC 18E .0401 Table II[17] |
| North Carolina | Wastewater: no-hookup (onsite-18E) | 70 | gal | per campsite, bathhouse for campsites and RV sites with no water and sewer hookups, max 4 people | 15A NCAC 18E .0401 Table II[17] |
| North Carolina | Wastewater: tent (onsite-18E) | 70 | gal | per campsite, same bathhouse category | 15A NCAC 18E .0401 Table II[17] |
| North Carolina | Wastewater: park-model (onsite-18E) | 150 | gal | per space, recreational park trailer or park model trailer, 400 sf or less | 15A NCAC 18E .0401 Table II[17] |
| North Carolina | Wastewater: full-hookup (non-discharge-02T) | 100 | gal | per campsite, campgrounds with water and sewer hookups (non-discharge permits) | 15A NCAC 02T .0114[18] |
| North Carolina | Wastewater: no-hookup (non-discharge-02T) | 75 | gal | per campsite, with comfort station, no hookups (non-discharge permits) | 15A NCAC 02T .0114[18] |
| North Carolina | Wastewater: tent (non-discharge-02T) | 75 | gal | per campsite (non-discharge permits) | 15A NCAC 02T .0114[18] |
| North Carolina | Wastewater: dump-station (non-discharge-02T) | 50 | gal | per space, campground dump station facility (non-discharge permits) | 15A NCAC 02T .0114[18] |
| Texas | Wastewater: full-hookup | 50 | gpd | per space (travel trailer/RV park), no water-saving devices | 30 TAC §285.91(3) Table III[16] |
| Texas | Wastewater: full-hookup | 40 | gpd | per space (travel trailer/RV park), with water-saving devices | 30 TAC §285.91(3) Table III[16] |
| Texas | Wastewater: per-person | 15 | gpd | per person, park with bathhouse, no water-saving devices (Texas sets no separate value for RV sites without hookup; tent sites use the same per-person rates) | 30 TAC §285.91(3) Table III[16] |
| Texas | Wastewater: per-person | 12 | gpd | per person, park with bathhouse, with water-saving devices | 30 TAC §285.91(3) Table III[16] |
| Texas | Wastewater: per-person | 10 | gpd | per person, park without bathhouse, no water-saving devices | 30 TAC §285.91(3) Table III[16] |
| Texas | Wastewater: per-person | 8 | gpd | per person, park without bathhouse, with water-saving devices | 30 TAC §285.91(3) Table III[16] |
Design flows not verified in our research: Alabama, Alaska, Arizona, Arkansas, California, Colorado, Connecticut, Delaware, District of Columbia, Georgia, Hawaii, Idaho, Illinois, Indiana, Iowa, Kansas, Kentucky, Louisiana, Maine, Maryland, Massachusetts, Minnesota, Mississippi, Missouri, Montana, Nebraska, Nevada, New Hampshire, New Jersey, New Mexico, New York, North Dakota, Ohio, Oklahoma, Oregon, Pennsylvania, Rhode Island, South Carolina, South Dakota, Tennessee, Utah, Vermont, Virginia, Washington, West Virginia, Wisconsin, Wyoming.
Review and water system thresholds
| Jurisdiction | Test | Value as stored | Unit | Condition | Citation |
|---|---|---|---|---|---|
| National | Public water system: service connections | 15 | service connections | at least: a public water system has at least 15 service connections | 40 CFR 141.2[20] |
| National | Public water system: persons served | 25 | individuals daily (average) | at least: regularly serves an average of at least 25 individuals daily, at least 60 days a year | 40 CFR 141.2[20] |
| National | Public water system: days a year | 60 | days a year | at least 60 days a year, with the 25-individual test | 40 CFR 141.2[20] |
| National | Public water system class | transient non-community system (agency guidance) | a campground is typically this class of public water system | [30] | |
| Massachusetts | Public water system: service connections | 15 | connections | 15 connections | MassDEP guidance[36] |
| Massachusetts | Public water system: persons served | 25 | individuals daily | 25 individuals daily at least 60 days | MassDEP guidance[36] |
| Massachusetts | Public water system: days a year | 60 | days | at least 60 days, with the 25-individual test | MassDEP guidance[36] |
| Massachusetts | Public water system: systems combined | MassDEP may aggregate commonly owned wells | MassDEP guidance[36] | ||
| Michigan | Construction permit | Any campground construction or alteration needs an EGLE construction permit | any construction or alteration | MCL 333.12505[10] | |
| Michigan | Engineer-prepared plans | $15,000 | project cost | above: plans for projects costing more than $15,000 must be engineer-prepared | R 325.1553(1)[10] |
| North Carolina | Local health department approval | 1,500 | gpd | up to: the local health department may approve RV park systems up to 1,500 gpd (about 15 RV spaces or 10 park model spaces) | NCDHHS RV Parks Guidance (18E version)[19] |
| North Carolina | State review: design daily flow | 3,000 | gpd | above: state review is required above 3,000 gpd unreduced design daily flow | NCDHHS RV Parks Guidance (18E version)[19] |
| North Carolina | State review: pretreatment | unapproved advanced pretreatment | state review is required for unapproved advanced pretreatment | NCDHHS RV Parks Guidance (18E version)[19] | |
| North Carolina | State review: dump-station waste | any system receiving dump-station waste | state review is required for any system receiving dump-station waste | NCDHHS RV Parks Guidance (18E version)[19] | |
| Nevada | Public water system: service connections | 15 | service connections | 15 or more | NRS 445A.235[37] |
| Nevada | Public water system: persons served | 25 | persons | regularly serves 25 or more persons | NRS 445A.235[37] |
| Texas | Public water system test | 15/25/60 | the same 15 connection, 25 person, 60 day test as the federal floor | 30 TAC §290.38[32] | |
| Texas | Public water system: systems combined | Adjacent systems under common ownership are combined | 30 TAC §290.38[32] | ||
| Texas | Transient non-community water system: persons | 25 | persons | transient non-community: 25 persons at least 60 days | 30 TAC §290.38[32] |
| Texas | On-site sewage facility program ceiling | 5,000 | gallons per day | below: Chapter 285 OSSF rules apply to an RV park only with combined wastewater flow of less than 5,000 gallons per day; at 5,000 gpd or more the OSSF program does not apply | 30 TAC §285.2(59)[16] |
Not verified in our research: which permit applies at or above the OSSF ceiling (Texas); a state-specific public water system threshold (Florida); the flow above which a state or large-system wastewater permit applies (Florida); a state-specific public water system threshold (North Carolina); a state-specific public water system threshold (California); the flow above which a state or large-system wastewater permit applies (California); the flow above which a state or large-system wastewater permit applies (Nevada); the flow above which a state or large-system wastewater permit applies (Massachusetts).
Fixtures, dump stations and water stations
| Jurisdiction | Fixture | Value as stored | Unit | Condition | Citation |
|---|---|---|---|---|---|
| Florida | Toilets | 1 | toilet | minimum per park; same set repeated for each 25 non-self-contained spaces or fraction | 64E-15.004(5) to (7)[5] |
| Florida | Urinals | 1 | urinal | minimum per park; same set repeated for each 25 non-self-contained spaces or fraction | 64E-15.004(5) to (7)[5] |
| Florida | Toilets | 2 | toilets | minimum per park; same set repeated for each 25 non-self-contained spaces or fraction | 64E-15.004(5) to (7)[5] |
| Florida | Lavatories | 1 | lavatory per sex | minimum per park; same set per 25 non-self-contained spaces | 64E-15.004(5) to (7)[5] |
| Florida | Dump stations | 1 | dump station | per 100 spaces or fraction | 64E-15.005(2) to (3)[5] |
| Florida | Dump stations | 1 | dump station | per 250 spaces or fraction when more than 50 percent of spaces have sewer hookups | 64E-15.005(2) to (3)[5] |
| Florida | Potable water stations | 1 | potable water station | per 100 non-hookup spaces | 64E-15.003(3)(b)[5] |
| Florida | Potable water stations | 1 | potable water station | per 250 when more than 50 percent are hooked up | 64E-15.003(3)(b)[5] |
| Florida | Bathhouse exemption | A full-hookup, self-contained-only park may file an exemption letter | full-hookup park serving self-contained units only | 64E-15.005(6)[5] | |
| Florida | Toilets | 1:10 | recreational camps; tents count as 2 people, split equally by gender | 64E-15.009(7)(a)[5] | |
| Florida | Toilets | 1:15 | recreational camps; tents count as 2 people, split equally by gender | 64E-15.009(7)(a)[5] | |
| Florida | Urinals | 1:25 | recreational camps; tents count as 2 people, split equally by gender | 64E-15.009(7)(a)[5] | |
| Florida | Lavatories | 1:10 | recreational camps; tents count as 2 people, split equally by gender | 64E-15.009(7)(a)[5] | |
| Florida | Lavatories | 1:15 | recreational camps; tents count as 2 people, split equally by gender | 64E-15.009(7)(a)[5] | |
| Florida | Showers | 1:15 | recreational camps; tents count as 2 people, split equally by gender | 64E-15.009(7)(a)[5] | |
| Duval County, Florida | Portable toilets | 2 | portable toilets | temporary RV parks: per 25 spaces | Sec. 460.304 to 460.305[33] |
| Duval County, Florida | Dump stations | 1 | dump station | temporary RV parks: per 100 spaces | Sec. 460.304 to 460.305[33] |
| Duval County, Florida | Water stations | 1 | water station | temporary RV parks: per 100 spaces | Sec. 460.304 to 460.305[33] |
| Palm Bay, Florida | Dump stations | 1 | dump station | at least 1 dump station | Code §174.045[6] |
| Palm Bay, Florida | Dump stations | 1 | additional dump station | 1 more per 50 non-sewered sites beyond the first 50 | Code §174.045[6] |
| Palm Bay, Florida | Bathhouse fixtures | 2 | of each fixture per sex | each bathhouse, within 300 ft of non-hookup sites, at least 2 of each fixture per sex | Code §174.045[6] |
| Michigan | Showers | 1 | shower per sex | showers are optional; if provided, more than 250 sites need 1 per sex per 50 sites (fixture schedule applies to sites without water and sewer) | R 325.1571(4), (5)[10] |
| Michigan | Showers | 1 | shower | showers are optional; if provided, more than 250 sites need 1 per 30 sites (unisex schedule) | R 325.1571(4), (5)[10] |
| Michigan | Dump stations | A sanitary station is required | R 325.1576[10] | ||
| Michigan | Privies | 1 | privy per sex | primitive campground: per 25 sites; privies at least 50 ft from sites | R 325.1556a(1)[10] |
| Michigan | Privies | 2 | unisex privies | primitive campground: alternative to 1 privy per sex, per 25 sites | R 325.1556a(1)[10] |
| Michigan | Water outlets | a water outlet | primitive campground: per 25 sites | R 325.1556a(1)[10] | |
| Michigan | Privies | 1 | unisex privy | primitive areas of 10 sites or fewer may use 1 unisex privy | R 325.1556a(1)[10] |
| Michigan | Privies | 1 | privy per sex | temporary primitive campground (operation up to 4 weeks): per 25 sites | R 325.1555(2), R 325.1555a[10] |
| Michigan | Privies | 2 | unisex privies | temporary primitive campground (operation up to 4 weeks): per 30 sites | R 325.1555(2), R 325.1555a[10] |
| Michigan | Dump stations | 1 | sanitary station | temporary campground (operation up to 4 weeks): 1 sanitary station required | R 325.1555(2), R 325.1555a[10] |
| Michigan | Water outlets | 1 | water outlet | temporary campground (operation up to 4 weeks): per 50 sites | R 325.1555(2), R 325.1555a[10] |
| Sebewaing, Michigan | Toilets | 1 | toilet | per 8 sites (local, stricter than state) | §153.098[38] |
| Sebewaing, Michigan | Lavatories | 1 | sink | per 8 sites (local, stricter than state) | §153.098[38] |
| Oregon | Lavatories | 1 | additional lavatory per 2 toilets | when more than 6 toilets are required: 1 additional lavatory per 2 toilets | OAR 918-650-0050 Table 3-RV (eff. 4/1/1988)[39] |
| Oregon | Urinals | 1/3 | of men's toilets | urinals may replace up to 1/3 of men's toilets | OAR 918-650-0050 Table 3-RV (eff. 4/1/1988)[39] |
| Sutherlin, Oregon | Washers | 1 | washer | per 30 spaces | SMC 12.40.090[7] |
| Sutherlin, Oregon | Dryers | 1 | dryer | per 30 spaces | SMC 12.40.090[7] |
| Sutherlin, Oregon | Sanitary fixture schedule | parks over 30 spaces follow OAR 918-650-0050 | parks over 30 spaces | SMC 12.40.090[7] |
No statewide fixture ratio verified in our research: Alabama, Alaska, Arizona, Arkansas, California, Colorado, Connecticut, Delaware, District of Columbia, Georgia, Hawaii, Idaho, Illinois, Indiana, Iowa, Kansas, Kentucky, Louisiana, Maine, Maryland, Massachusetts, Minnesota, Mississippi, Missouri, Montana, Nebraska, Nevada, New Hampshire, New Jersey, New Mexico, New York, North Carolina, North Dakota, Ohio, Oklahoma, Pennsylvania, Rhode Island, South Carolina, South Dakota, Tennessee, Texas, Utah, Vermont, Virginia, Washington, West Virginia, Wisconsin, Wyoming.
Electrical tables, as secondary reproductions
The NEC is a model code each state adopts by edition; which edition a state has adopted is not verified in our research. Every value below is labelled with the kind of source it comes from.
| Part | Value as stored | Unit | Condition | Edition | Citation |
|---|---|---|---|---|---|
| Receptacles | Required at each site with electrical supply (secondary reproduction of a code table) | 20 A, 125 V receptacle | 2014 | NEC 551.71(A)[40] | |
| Receptacles | 70 (secondary reproduction of a code table) | percent of all sites with electrical supply | minimum; 30 A, 125 V, weather-resistant, conforming to Figure 551.46(C)(1) | 2023 | NEC 551.71(B)[11] |
| Receptacles | 40 (secondary reproduction of a code table) | percent of new sites | minimum, new sites; 50 A, 125/250 V | 2017 onward; carried in 2023 | NEC 551.71(C)[11] |
| Receptacles | 20 (secondary reproduction of a code table) | percent of existing sites | minimum, existing sites; 50 A, 125/250 V | 2017 onward; carried in 2023 | NEC 551.71(C)[11] |
| Receptacles | 20 (secondary reproduction of a code table) | percent of new sites | new sites under NEC editions before 2017 (raised from 20 to 40 percent for new sites in the 2017 NEC) | before 2017 | NEC 551.71(C)[12] |
| Receptacles | Every site with a 50 A receptacle must also have a 30 A, 125 V receptacle (secondary reproduction of a code table) | 2014 onward | NEC 551.71(C)[41] | ||
| Receptacles | Dedicated tent sites with 15 or 20 A supply may be excluded when computing the 30 A and 50 A percentages (secondary reproduction of a code table) | applies to dedicated tent sites only | 2020 text | NEC 551.71[13] | |
| Receptacles | 100 (secondary reproduction of a code table) | percent of sites (could approach) | advisory informational note, not mandatory: the 50 A share could approach 100 percent in parks serving seasonal and large RVs | 2020 and 2023 | NEC 551.71 informational note[12] |
| Load per site | 12,000 (secondary reproduction of a code table) | VA per site | 50 A site (208Y/120 or 120/240 V) | 2017 onward; 2023 confirmed | NEC 551.73(A)[14] |
| Load per site | 9,600 (secondary reproduction of a code table) | VA per site | 50 A site under NEC editions before 2017 | before 2017 | NEC 551.73(A)[14] |
| Load per site | 3,600 (secondary reproduction of a code table) | VA per site | site with both 20 A and 30 A | 2017 and 2023 | NEC 551.73(A)[14] |
| Load per site | 2,400 (secondary reproduction of a code table) | VA per site | site with 20 A only | 2017 and 2023 | NEC 551.73(A)[14] |
| Load per site | 600 (secondary reproduction of a code table) | VA per site | dedicated tent site with 20 A only | 2017 and 2023 | NEC 551.73(A)[14] |
| Load per site | Calculate only for the highest-rated receptacle (secondary reproduction of a code table) | multiple receptacles at one site | 2023 text | NEC 551.73(A)[15] | |
| Demand factor note | Demand factors do not apply to bathhouses, recreation buildings, pools and similar loads (secondary reproduction of a code table) | 2017 onward | NEC 551.73(A)[14] | ||
| Demand factor note | the demand factor for a given number of sites applies to all sites indicated (secondary reproduction of a code table) | NEC 551.73(B)[42] | |||
| Demand factor note | The table sets the minimum allowable demand factors (secondary reproduction of a code table) | NEC 551.73(B)[42] | |||
| Demand factor | 100 (secondary reproduction of a code table) | percent | 1 RV site | NEC Table 551.73(A)[43] | |
| Demand factor | 90 (secondary reproduction of a code table) | percent | 2 RV sites | NEC Table 551.73(A)[43] | |
| Demand factor | 80 (secondary reproduction of a code table) | percent | 3 RV sites | NEC Table 551.73(A)[43] | |
| Demand factor | 75 (secondary reproduction of a code table) | percent | 4 RV sites | NEC Table 551.73(A)[43] | |
| Demand factor | 65 (secondary reproduction of a code table) | percent | 5 RV sites | NEC Table 551.73(A)[43] | |
| Demand factor | 60 (secondary reproduction of a code table) | percent | 6 RV sites | NEC Table 551.73(A)[42] | |
| Demand factor | 55 (secondary reproduction of a code table) | percent | 7 to 9 RV sites | NEC Table 551.73(A)[43] | |
| Demand factor | 50 (secondary reproduction of a code table) | percent | 10 to 12 RV sites | Table 551.73 reproduction, 2007 California Electrical Code | NEC Table 551.73(A)[43] |
| Demand factor | 48 (secondary reproduction of a code table) | percent | 13 to 15 RV sites | Table 551.73 reproduction, 2007 California Electrical Code | NEC Table 551.73(A)[43] |
| Demand factor | 47 (secondary reproduction of a code table) | percent | 16 to 18 RV sites | Table 551.73 reproduction, 2007 California Electrical Code | NEC Table 551.73(A)[43] |
| Demand factor | 45 (secondary reproduction of a code table) | percent | 19 to 21 RV sites | NEC Table 551.73(A)[15] | |
| Demand factor | 43 (secondary reproduction of a code table) | percent | 22 to 24 RV sites | Table 551.73 reproduction, 2007 California Electrical Code | NEC Table 551.73(A)[43] |
| Demand factor | 42 (secondary reproduction of a code table) | percent | 25 to 35 RV sites | NEC Table 551.73(A)[44] | |
| Demand factor | 41 (secondary reproduction of a code table) | percent | 36 and over RV sites | NEC Table 551.73(A)[14] |
Densities observed in approvals
Observed in approvals, not a code limit, and not applied to the acreage: the density statistics and clusters in our research are computed over a set of approvals that includes machine-written meeting summaries, so they are not shown and the calculator estimates no site count from them. Each approval below rests on a primary document or carries its secondary label. 13 further approvals in the set are not shown: their outcome, their figures or their source could not be checked against a primary document in our research.
| Project | Where | Value as stored | Unit | Condition |
|---|---|---|---|---|
| Rhoades RV Park | Uintah County, Utah | 22.2 (observed in approvals)[1] | sites per gross acre | Planning Commission CUP, 6/18/2025, unanimous; 38 RV sites on 1.71 gross acres |
| West Atlantic RV Resort (ZV/SV/PDD-2024-01422) | Palm Beach County, Florida | 12.0 (observed in approvals)[3] | sites per gross acre | Zoning Commission hearing 5/1/2025, staff recommended approval; BCC land-use transmittal capped the site at 121 spaces; 113 RV plus 8 camping cabins on 10.11 gross acres (11.2 per acre RV only); the final BCC adoption date is unverified |
| Jantzer RV Park (201-00553-26) | Grants Pass, Oregon | 14.9 (observed in approvals)[2] | sites per gross acre | Urban Area Planning Commission, major site plan approved 7-0 (re-review of a 2024 approval; packet dated 3/25/2026); 87 RV sites in two phases on 5.83 gross acres |
| Woods Hollow RV Park (APA P2022-0008) | Town of Mayfield, Fulton County, New York | 3.3 (observed in approvals)[4] | sites per gross acre | Adirondack Park Agency, unanimous, 12/15/2022 (after county and town planning boards); 277 sites (RV, glamping and primitive) on 83.4 acres; agency figure 3.5 |
| North Pasco Resort | Pasco County, Florida | 2.7 (observed in approvals)[45] | sites per gross acre | secondary source (trade press, not a county record): BCC 3-2, January 6, 2026; 350 RV on 131 gross acres that include a 250-room hotel (mixed use); per a second press report (Hernando Sun), the amendment cut RV spaces from 550 to 350 |
Trip rate and design vehicle
| Item | Value as stored | Unit | Condition or edition | Citation |
|---|---|---|---|---|
| Trip rate, land use 416, pm-peak | 0.27 (published trip rate) | trips per occupied campsite | ITE Trip Generation, 11th Edition (2021), as republished in the City of Phoenix, OR SDC table | [21] |
Campground parking
| Jurisdiction | Value as stored | Unit | Condition | Citation |
|---|---|---|---|---|
| Tucson, Arizona | 1 | per campsite | Travelers' Accommodation, Campsite | UDC Sec. 7.4.4, Table 7.4.4-1[27] |
| Michigan | 1.5 | spaces per site | on sites or in a separate lot; all campgrounds | Mich. Admin. Code R 325.1558(2)[10] |
| Tulsa, Oklahoma | 0.65 | per camping space | Campgrounds and RV parks; all districts other than CBD | Tulsa Zoning Code Sec. 55.020, Table 55-1 (Ord. 25429, eff. 12/10/2024)[46] |
| Houston, Texas | not codified | Code of Ordinances Sec. 26-492[28] | ||
| Milwaukee, Wisconsin | not codified | Table 295-403-2-a[29] |
Not verified in our research
Every rule our research holds for these counties and cities is withheld, so the calculator applies only their state's rules there:
- Phoenix, Arizona
- Los Angeles, California
- Jacksonville, Florida
- Louisiana parish (jurisdiction unverified), Louisiana
- Nye County, Nevada
- Dallas, Texas
- Fort Worth, Texas
- San Antonio, Texas
- Utah county (jurisdiction name not shown in document), Utah
- Clallam County, Washington
Not set in any code our research retrieved, so the calculator sizes none of them:
- Pad dimensions by RV class
- Pull-through and back-in site lengths
- A minimum turning radius set in a code
- Industry dimensional guidance for pads
The NEC edition in force is not verified in our research for any state.
Worked examples
Computed by the calculator's own engine from the rows above when this page was built.
- Gross acres
- 4
- State
- NC
- Full-hookup RV sites
- 20
- Sites with a fifty amp receptacle, entered
- 0
- Site mix
- Observed density
- Density cap
- Meets:
- Below the minimum:
- Edition logic
- Design flow total, gallons per day
- ()
- Design flow total, gallons per day
- ()
- Crossed:
- Needs an input:
- Crossed:
- Not crossed:
- PM peak hour trips
- Not verified in our research
- ; ; ; ; ; ;
- Gross acres
- 4
- State
- FL
- Full-hookup RV sites
- 120
- Site mix
- Observed density
- Binds:
- Density cap
- Meets:
- Meets:
- Edition logic
- Design flow total, gallons per day
- ()
- Crossed:
- Needs an input:
- Applies:
- PM peak hour trips
- Not verified in our research
- ; ; ; ; ; ;
What the calculator leaves out
Our research verified per-site design flows for Texas, Michigan, North Carolina and Florida, whose flows come from the rule text of 62-6.008 opened for this edition. For every other state the calculator reports the design flow as not verified in our research and computes no total. Fixture ratios are verified statewide for Florida and Michigan, in part for Oregon, and for a few counties and cities; for Texas, North Carolina and the other states they are not verified in our research.
The public water system class is stated, not computed: a campground is typically a transient non-community system [30]. Cabins are not an input either; in Michigan, camping cabins under 400 sf with no water connection carry no separate flow, and resort cabins with fixtures need EGLE evaluation [31].
Which NEC edition each state has adopted is not verified in our research, and neither is the text of the newest edition of 551.71 and 551.73. No state code in our research sets pad dimensions by RV class, pull-through or back-in lengths or a minimum turning radius, so the calculator sizes none of them.
No density observed in approvals is applied to the acreage: the statistics and clusters in our research rest in part on machine-written meeting summaries, so they are not shown, and the approvals shown are evidence, not a code limit. A cap, a minimum park size or a fixture ratio the calculator does not list for a county or city is not verified in our research, which is not the same as no rule. The result is a preliminary estimate for a site plan; the engineer of record sizes the electrical service, the wastewater system and the roads, and the RV park regulations by state guide covers the approval path.
Frequently asked questions
How many RV sites fit on an acre?
It depends on the code and the program. Florida caps RV parks at 25 RV units per gross acre [5], Palm Bay at 15 RV sites per gross acre [6] and Alamosa County at 8 sites per acre on average [8]. Approved parks vary widely: Grants Pass approved Jantzer RV Park with 87 RV sites on 5.83 gross acres, or 14.9 per acre [2], and the Adirondack Park Agency approved Woods Hollow RV Park with 277 sites on 83.4 acres, or 3.3 per acre [4].
What electrical service does an RV park need?
NEC 551.71 requires 30 A receptacles at 70 percent of electrified sites and 50 A receptacles at 40 percent of new sites, with every 50 A site also carrying a 30 A receptacle [11]. Under 551.73(A) the load is calculated at 12,000 VA per 50 A site and 3,600 VA per site with both 20 A and 30 A, and Table 551.73(A) demand factors fall from 100 percent at 1 site to 41 percent at 36 or more sites [14].
How much wastewater does an RV park generate?
When does an RV park need state wastewater review in North Carolina?
State review is required above 3,000 gpd unreduced design daily flow, for unapproved advanced pretreatment or for any system receiving dump-station waste, and the local health department may approve RV park systems up to 1,500 gpd [19]. At 100 gpd per space, an NC park crosses into state review at about 30 full-hookup sites [17, 19].
Is an RV park a public water system?
How many PM peak hour trips does an RV park generate?
How wide do RV park roads need to be?
Road widths start from NFPA 1194, a model standard for recreational vehicle parks and campgrounds [23]. For roads designed for all camping unit types and sizes, it sets 10 ft per traffic lane and 8 ft per parallel parking lane [23]. Adopted codes vary: Fruita, Colorado, which adopts NFPA 1194 by reference, requires 28 ft two-way roads and 20 ft one-way roads [25], and Michigan requires a 20 ft minimum road right-of-way [10].
Sources
- 1)Uintah County Planning Commission minutes, Rhoades RV Park conditional use permit, Uintah County, on the Utah Public Notice Website. Accessed 2026-10-11.
- 2)Urban Area Planning Commission meeting minutes and packet, March 25, 2026 (Jantzer RV Park, 201-00553-26), City of Grants Pass. Accessed 2026-10-11.
- 3)West Atlantic RV Resort Staff Report, Palm Beach County Zoning Commission. Accessed 2026-10-11.
- 4)Woods Hollow RV Park (P2022-0008), comment response, Adirondack Park Agency. Accessed 2026-10-11.
- 5)Chapter 64E-15, F.A.C., Mobile Home, Lodging, and Recreational Vehicle Parks and Recreational Camps (2018 version), Florida Department of Health. Accessed 2026-10-11.
- 6)Code of Ordinances § 174.045, Recreational Vehicle Parks, City of Palm Bay. Accessed 2026-10-11.
- 7)Municipal Code Chapter 12.40, Recreational Vehicle Parks and Campgrounds, City of Sutherlin. Accessed 2026-10-11.
- 8)Alamosa County Text Amendments to the Land Use Development Code TA 25-001, Alamosa County. Accessed 2026-10-11.
- 9)Parker County Infrastructure Requirements for Recreational Vehicle Parks, Parker County. Accessed 2026-10-11.
- 10)Campground rules, Part 125 of Act 368 (R 325.1551 and following), Michigan Department of Environment, Great Lakes, and Energy. Accessed 2026-10-11.
- 11)551.71(A)(B)(C)(F) Receptacle Requirements at RV Parks. Accessed 2026-10-11.
- 12)Type Receptacles Provided (Recreational Vehicle Parks). Accessed 2026-10-11.
- 13)Article 551. Accessed 2026-10-11.
- 14)Sizing RV-Park Electrical Services Using NEC Table. Accessed 2026-10-11.
- 15)Attachment 15. Accessed 2026-10-11.
- 16)30 TAC Chapter 285, On-Site Sewage Facilities, Texas Commission on Environmental Quality. Accessed 2026-10-11.
- 17)15A NCAC 18E .0401, Design daily flow, North Carolina Office of Administrative Hearings. Accessed 2026-10-11.
- 18)15A NCAC 02T .0114, Wastewater design flow rates, North Carolina Office of Administrative Hearings. Accessed 2026-10-11.
- 19)RV Parks Guidance (18E version), North Carolina Department of Health and Human Services. Accessed 2026-10-11.
- 20)40 CFR 141.2, Definitions, Electronic Code of Federal Regulations. Accessed 2026-10-11.
- 21)ITE Trip Generation Manual, 11th Edition (system development charge table), City of Phoenix, Oregon. Accessed 2026-10-11.
- 22)Land Use: 416 Campground/Recreational Vehicle Park Description (CUP2024-00005), Whatcom County. Accessed 2026-10-11.
- 23)Standard for Recreational Vehicle Parks and Campgrounds, NFPA 1194, 2021 edition (preview), National Fire Protection Association. Accessed 2026-10-11.
- 24)OAR chapter 918, division 650, Oregon Secretary of State. Accessed 2026-10-11.
- 25)Municipal Code Chapter 17.33, Campgrounds and Recreational Vehicle Parks, City of Fruita. Accessed 2026-10-11.
- 26)Roadway Design Manual 4.3.3, Control Vehicles, Texas Department of Transportation. Accessed 2026-10-11.
- 27)Unified Development Code Sec. 7.4.4, Required Number of Motor Vehicle Parking Spaces, City of Tucson. Accessed 2026-10-11.
- 28)Code of Ordinances Sec. 26-492, parking requirements, City of Houston, Planning and Development Department. Accessed 2026-10-11.
- 29)Code of Ordinances Ch. 295, subchapter 4 (s. 295-403, Table 295-403-2-a), City of Milwaukee, Office of the City Clerk. Accessed 2026-10-11.
- 30)Introduction to the Safe Drinking Water Act and its requirements (presentation), U.S. Environmental Protection Agency. Accessed 2026-10-11.
- 31)Cabins and Park Models in Campgrounds (Rev. 8/2025), Michigan Department of Environment, Great Lakes, and Energy. Accessed 2026-10-11.
- 32)What is a Public Water System?, Texas Commission on Environmental Quality. Accessed 2026-10-11.
- 33)Sec. 460.301. Temporary Recreation Vehicle (RV) park .... Accessed 2026-10-11.
- 34)Oregon Secretary of State Administrative Rules. Accessed 2026-10-11.
- 35)Rule 62-6.008. Accessed 2026-10-12.
- 36)Determining if a water system is public or private. Accessed 2026-10-11.
- 37)Definitions and Regulations. Accessed 2026-10-11.
- 38)§ 153.098 RECREATIONAL VEHICLE PARK, CAMPGROUND.. Accessed 2026-10-11.
- 39)Table 3-RV Sanitary Facilities (918-650-0050. Accessed 2026-10-11.
- 40)Recreational Vehicles and RV Parks. Accessed 2026-10-11.
- 41)Quantity and Types of Receptacles at RV Parks. Accessed 2026-10-11.
- 42)post 2715909. Accessed 2026-10-11.
- 43)551.74 ARTICLE 551- RECREATIONAL VEHICLES AND RECREATIONAL VEHICLE PARKS. Accessed 2026-10-11.
- 44)RV Park Demand Calculation (551.73). Accessed 2026-10-11.
- 45)Woodall's, Jan. 13, 2026. Accessed 2026-10-11.
- 46)Tulsa Zoning Code Sec. 55.020, Table 55-1 as amended by Ord. 25429. Accessed 2026-10-12.
Rules as researched on October 11, 2026. Each row of the table carries its own date.
Start a project with these numbers
Send the site and the program. The studio reads your inputs and the result above with the brief, and replies to scope the preliminary site plan.